709H - 

Precision Hart Loop Calibrator

Fluke 709H
声明:图片仅供参考,请以实物为准!
制造商:
Fluke Fluke
制造商产品编号:
709H
仓库库存编号:
70272100
技术数据表:
View 709H Datasheet Datasheet
订购热线: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于产品数据库庞大,部分产品信息可能未能及时更新,下单前请与销售人员确认好实时在库数量,谢谢合作!

709H产品概述

Fluke reliable. HART compatible.
Fluke puts HART communication in a precision loop calibrator.

The Fluke 709 and 709H mA loop calibrators are designed to save time and produce high-quality results. These calibrators are built around a user friendly interface with a quick-set rotary encoder knob. This tool reduces the time it takes to measure, or source, current and power up a loop. The protective holster easily fits into a technician's hand and the large backlit display is easy to read, even in dark, cramped worked areas.

Features:
  • Best-in-class accuracy at 0.01% reading
  • Compact rugged design
  • Intuitive user interface with quick-set knob for fast setup, easy use
  • 24 V dc loop power with mA measure mode (–25% to 125%)
  • Resolution of 1 μA on mA ranges and 1 mV on voltages ranges
  • Built in selectable 250 Ω resistor for HART communications
  • Simple two wire connection for all measurements
  • Auto shutdown to conserve battery life
  • Variable step and ramp time in seconds
  • Valve test (source and simulate defined mA values with % keys)

    HART communication
    The Fluke 709H offers a built-in HART modem for communication capability to perform the following commands:
  • Read message
  • Read tag, descriptor, calibration date
  • Read sensor PV information
  • Read PV output information
  • Read long tag
  • Write PV ranges (upper and lower)
  • Enter/exit fixed current mode
  • Set zero offset
  • Trim DAC zero (mA output 4 mA)
  • Trim DAC gain (mA output 20 mA)
  • The Fluke 709H also offers ability to store up to twenty HART device configuration files for uploading via 709H/TRACK software. Configurations can be stored as .csv or .txt files. This allows the end user to document plant HART easily.

    Configurations can be stored as .csv or .txt files. This feature gives the technician direct access to key device parameters, allowing better troubleshooting, calibrating and maintaining of plant assets.
  • 709H产品信息

      Type  Loop  
    关键词         
    电话:400-900-3095
    QQ:800152669
    关于我们 | Amphenol简介 | Amphenol产品 | Amphenol产品应用 | Amphenol动态 | 按系列选型 | 按产品规格选型 | Amphenol选型手册 | 付款方式 | 联系我们
    Copyright © 2017 www.amphenol-connect.com All Rights Reserved. 技术支持:电子元器件 ICP备案证书号:粤ICP备11103613号